Camjoy MS101A Urology Morcellator System (26Fr, Dedicated HoLEP Tissue Extraction)

    ✅ 2-Year Warranty   |   ✈️ Worldwide Shipping

    Payment Methods:

    Description

    Camjoy MS101A Urology Morcellator System

    26Fr High-Efficiency Sheath | Z-Type Optics | Powerful Suction Shaver

    ✔ Offset Z-Type Endoscope


    ✔ 4.8mm High-Torque Blades


    ✔ Seamless System Integration

    Rapid, Safe, and Seamless Prostate Morcellation

    The final and most critical step of any Holmium Laser Enucleation of the Prostate (HoLEP) procedure is the safe and rapid extraction of the enucleated adenoma tissue from the bladder. The Camjoy MS101A Urology Morcellator System is engineered to perform this task with exceptional efficiency and unparalleled safety.

    At the core of the MS101A is the specially designed M2621 Z-type Endoscope. By offsetting the optical eyepiece, it creates a perfectly straight, unobstructed working channel. This allows the robust 4.8mm shaver blades to pass directly into the bladder, enabling simultaneous high-definition visualization, aggressive tissue aspiration, and mechanical morcellation.

    Seamless Workflow Integration: To optimize OR time and minimize urethral trauma, the MS101A is designed for total compatibility. If you are performing enucleation using our BRS108A 4mm/302mm Bipolar Resectoscope Set or the Camjoy LRS105A Laser Resectoscope Set, you do not need to remove the 26Fr outer sheath. The morcellator components lock directly into your existing 26Fr sheath, facilitating an instant transition from enucleation to extraction.

    Clinical Advantages

    • ✔ High-Speed Clearance: The CY2600 shaver system rapidly aspirates and cuts large adenoma lobes.
    • ✔ Straight-Line Access: The Z-type optic ensures the shaver blade never bends, preventing mechanical failure.
    • ✔ Atraumatic Workflow: Integrates directly with BRS108A/LRS105A sheaths, avoiding repetitive instrument insertions.
    • ✔ Precise Control: Responsive foot switch (CY2604) gives the surgeon instant start/stop command.
    • ✔ Enhanced Safety: Flared sealing and duckbill caps (A4513/A4514) maintain bladder distension perfectly.

    Engineering Excellence & Technology

    1. The M2621 Z-Type Endoscope

    Traditional endoscopes have the eyepiece in a straight line, forcing instruments to bend around them. The M2621 features a 0-degree, 200mm optic with an offset (Z-type) eyepiece. This brilliant architectural shift provides a straight working channel. The rigid 4.8mm shaver blade passes straight through, maximizing mechanical cutting force and completely eliminating blind spots during tissue engagement.

    2. CY2600 Urology Shaver System

    Tissue extraction requires aggressive, sustained mechanical power. The CY2600 console delivers high-torque rotation paired with integrated vacuum suction. As the 4.8mm blades (CY2602/CY2603) rotate at the tip, the suction continuously draws the floating prostatic adenoma into the cutting window, shaving it into fragments and transporting it directly to the effluent bottle (CY2605).

    3. Universal 26Fr Compatibility

    While the system includes its own dedicated S2618 Sheath (26Fr/180mm) and S2618A Obturator, its greatest asset is its cross-compatibility. The components perfectly match the outer sheaths of our Urology Resectoscope Systems. This modular approach saves hospitals money and significantly reduces OR turnover time.

    🌟 6 Key System Highlights

    🎥

    Z-Type Optics

    Offset eyepiece design provides a direct, straight-line working channel for rigid instruments while maintaining HD visualization.

    ⚙️

    High-Torque Shaver

    The CY2600 console delivers aggressive, unyielding rotational power to quickly break down the densest prostatic tissue.

    🔗

    Seamless Integration

    Eliminates sheath exchanges. Perfectly matches the 26Fr outer sheaths of Camjoy’s Bipolar and Laser Enucleation systems.

    🔪

    4.8mm Precision Blades

    Heavy-duty 4.8mm diameter (380mm length) blades draw tissue efficiently into the cutting window without clogging.

    💧

    Integrated Suction

    Creates a continuous vacuum effect that pulls floating adenoma lobes to the blade tip and safely evacuates the fragments.

    🛡️

    Dynamic Sealing

    A4513 Flared and A4514 Duckbill valve caps ensure zero fluid leakage, maintaining essential bladder distension during morcellation.

    📊 Detailed Ordering Information (MS101A)

    The MS101A is a comprehensive package containing the optics, sheaths, and electronic shaver system required for HoLEP tissue extraction.

    👉 Swipe table left/right to view more columns →
    Model No. Description Specification & Details
    I. Main Components (Optics & Hardware)
    M2621 Z-type Endoscope 0° | 200mm Length | Offset eyepiece (Matched with 9-15Fr instrument)
    S2618 Outer Sheath 26Fr | 180mm (Compatible with BRS108A & LRS105A outer sheaths)
    S2618A Obturator for S2618 Atraumatic tip for safe insertion
    A4513 Flared Sealing Cap Maintains instrument seal during movement
    A4514 Duckbill Valve Cap Prevents fluid loss when instruments are removed
    A4311 In-flow Valve Stainless Steel Luer Lock
    R3340 Cleaning Rod Ø 3mm | 340mm Length
    II. Shaver System & Accessories (Electronic Console & Disposables)
    CY2600 Urology Shaver System Main console unit with integrated suction control
    CY2601 Shaver Handpiece Ergonomic motorized handle
    CY2602 Shaver Blade (Reusable/Disposable options) Ø 4.8mm | 380mm Length | Inner cutting edge
    CY2603 Shaver Blade (Alternative profile) Ø 4.8mm | 380mm Length
    CY2604 Foot Switch Hands-free activation of rotation and suction
    CY2605 Effluent Bottle High-capacity canister for tissue fragment collection
    CY2606 Silicone Tube Medical-grade vacuum tubing

    ❓ Frequently Asked Questions & Maintenance

    Q: Do I need to buy the S2618 Sheath if I already own your Laser Resectoscope?
    A: Not necessarily. A major technical highlight of the MS101A system is that its internal components (the Z-type scope and blades) are engineered to fit perfectly inside the 26Fr outer sheaths of our Camjoy LRS105A and BRS108A sets. This prevents the surgeon from having to remove the sheath midway through the procedure.
    Q: Why is a Z-type Endoscope required?
    A: Shaver blades (CY2602) are long, rigid, fast-rotating metal tubes. They cannot bend. The Z-type (offset) endoscope moves the camera’s eyepiece and light post out of the central axis, creating a perfectly straight tunnel for the blade to pass through while the surgeon looks “over” it via the offset lens.