Camjoy LRS105A1 Laser Resectoscope Set with Plastic Handle (26Fr, Dedicated HoLEP System)

    ✅ 2-Year Warranty   |   ✈️ Worldwide Shipping

    Payment Methods:

    Description

    Camjoy LRS105A1 Laser Resectoscope Set

    26Fr Continuous Flow | Lightweight Plastic Handle | HoLEP Ready

    ✔ Precision Fiber Guides


    ✔ Ultra-Light Ergonomics


    ✔ Morcelloscope Compatible

    Redefining Precision in HoLEP Procedures

    As Holmium Laser Enucleation of the Prostate (HoLEP) and Thulium Laser Enucleation (ThuLEP) continue to set the new gold standard for BPH treatment, the demand for specialized, highly stable laser delivery systems has never been greater. The Camjoy LRS105A1 Laser Resectoscope System is purpose-built to meet this demand.

    Unlike traditional electrocautery systems, the LRS105A1 is designed specifically to guide and stabilize delicate laser fibers (ranging from 1.0mm to 1.6mm) during precise anatomical enucleation. Utilizing a robust 26Fr continuous flow sheath architecture, the system maintains a crystal-clear operative field even during rapid tissue separation and hemostasis.

    To guarantee maximum surgeon stamina during these intensive procedures, the LRS105A1 features a premium lightweight plastic working element. This passive mechanism provides exceptional ergonomic balance, drastically reducing the fulcrum weight in the surgeon’s hand compared to traditional all-metal assemblies.

    Clinical Advantages

    • ✔ Dedicated Laser Delivery: Interchangeable fiber adapters ensure pinpoint laser accuracy without vibration.
    • ✔ Perfect HoLEP Synergy: Sheath seamlessly accommodates urological morcellators for immediate tissue extraction.
    • ✔ Ultra-Light Ergonomics: Premium plastic working element minimizes wrist fatigue during long enucleations.
    • ✔ Superior Hemostasis View: 26Fr continuous flow quickly flushes blood and tissue debris.
    • ✔ Standard 4mm Optics: Utilizes standard HD endoscopes for brilliant, wide-angle illumination.

    Engineering Excellence & Technology

    1. Precision Laser Fiber Adapters

    The core of the LRS105A1 is its specialized fiber delivery system. The set includes a comprehensive suite of Laser Fiber Adapters (F5010 to F5016) designed to securely hold fibers ranging from ϕ1.0mm to ϕ1.6mm. This prevents “fiber whip” or lateral deflection when the laser fires, ensuring the energy is delivered exactly where the surgeon intends along the surgical capsule.

    2. Seamless Morcelloscope Integration

    A successful HoLEP procedure relies heavily on the efficiency of the morcellation phase. The 26Fr outer sheath (S2618-5A) is dimensionally calibrated to match standard urological tissue morcellators. Once the adenoma lobes are dropped into the bladder, the laser working element is simply clicked out, and the morcelloscope is inserted directly through the same sheath—eliminating the need for traumatic sheath exchanges.

    3. Lightweight Plastic Working Element

    Laser enucleation often requires sustained, meticulous movements. The W5001P Passive Working Element is constructed from medical-grade autoclavable polymer. By utilizing plastic instead of heavy stainless steel, the instrument’s center of gravity is shifted, vastly improving tactile feedback and significantly lowering the physical strain on the operating surgeon.

    4. High-Volume 26Fr Continuous Flow

    Laser surgery creates bubbles and distinct tissue fragments. The large gap between the 26Fr outer sheath and the 24Fr inner sheath creates a high-capacity evacuation channel. Clear irrigation flows in continuously to cool the laser tip, while bubbles and debris are rapidly drawn out, maintaining low intravesical pressure and a pristine visual field.

    🌟 6 Key System Highlights

    🔆

    Laser Optimized

    Replaces traditional electrodes with specialized fiber guides, tailored specifically for Holmium and Thulium laser therapies.

    🎯

    HoLEP Ready

    The 26Fr outer sheath is perfectly sized to accept morcellators, streamlining the transition from enucleation to extraction.

    🪶

    Lightweight Handle

    High-durability plastic working element (W5001P) provides unmatched ergonomic balance and reduces hand torque.

    🌊

    26Fr Optimal Flow

    Large dual-sheath capacity provides maximum continuous irrigation and suction to handle heavy debris and bubbles.

    🔍

    Standard 4mm Optics

    Engineered to house standard 302mm / 4mm telescopes, ensuring brilliant illumination without needing special lenses.

    🔒

    Click-Lock Design

    Rapid, rotational-free assembly ensures the 30° scope view perfectly aligns with the laser fiber tip at all times.

    📊 Detailed Ordering Information (LRS105A1)

    The LRS105A1 is a highly specialized system dedicated to laser enucleation. Below is the exhaustive component list, featuring full compatibility for various laser fiber diameters.

    👉 Swipe table left/right to view more columns →
    Model No. Description Specification & Details
    I. Main Components (Optics, Handles & Sheaths)
    4302.30 HD Endoscope (Red Ring) 30° | Ø 4mm | 302mm Length | Universal Compatibility
    W5001P Working Element (Passive) Laser Type | Plastic Handle | Click-Locked
    S2618-5A Outer Sheath with Obturator 26Fr | 180mm Length
    S2420-5A Inner Sheath with Obturator 24Fr | 200mm Length
    S2400-5A Inner Sheath Adaptor Click-Locked connecting bridge
    II. Laser Fiber Adapters (For precise fiber stabilization)
    F5010 Fiber Adapter For Ø 1.0mm Laser Fibers
    F5012 Fiber Adapter For Ø 1.2mm Laser Fibers
    F5013 Fiber Adapter For Ø 1.4mm Laser Fibers
    F5016 Fiber Adapter For Ø 1.6mm Laser Fibers
    III. Accessories & Valves
    A4311 / A4312 In-flow / Out-flow Valve Stainless Steel Luer Lock
    A8304 Irrigator Connector Secure fluid line connection
    A4305 / A4306 Huffman / Ellik Irrigator For manual tissue chip evacuation
    A4303 Sealed Cap 10 pcs per pack
    R3340 Cleaning Rod Ø 3mm | 340mm Length
    IV. Fistula Instruments (Complete Set)
    F1695 – F2495 Fistula Instruments 16Fr, 18Fr, 20Fr, 22Fr, 24Fr (All 95mm Length)

    ❓ Frequently Asked Questions & Maintenance

    Q: How does a Laser Resectoscope differ from a Bipolar Resectoscope?
    A: Instead of using electrical cables and wire cutting loops, the Laser Resectoscope utilizes an internal channel to guide a flexible laser fiber (e.g., Holmium or Thulium). It features specific Fiber Adapters to hold the fiber perfectly steady, enabling precise anatomical enucleation without electrical current.
    Q: How does this system integrate with Morcellators?
    A: The LRS105A1 26Fr outer sheath (S2618-5A) is dimensionally calibrated to accommodate standard urological morcelloscopes. After enucleating the prostate lobes with the laser, you simply remove the working element and insert the morcellator directly into the existing sheath for tissue extraction.
    Q: Are the plastic working elements fully autoclavable?
    A: Absolutely. The W5001P handle is manufactured from advanced, medical-grade thermoresistant polymers that withstand standard steam autoclaving (134°C / 273°F) perfectly, offering the distinct advantage of being significantly lighter than metal handles.