Camjoy 4K 3D FPGA UHD endoscope camera 03
Camjoy CP701 Dual 4K Fluorescence Endoscopy Camera System | ICG Imaging for Surgical Oncology & Perfusion Original price was: $8,000.00.Current price is: $7,800.00.
Back to products
Camjoy Medical Endoscopy Cart 01
Camjoy CT101 Medical Endoscopy Cart | High-Stability Mobile Imaging Workstation for OR/Clinic Original price was: $1,200.00.Current price is: $800.00.

Camjoy CP702 Dual 4K Fluorescence Endoscopy Camera System | ICG Imaging for Surgical Oncology & Perfusion

Original price was: $8,000.00.Current price is: $7,800.00.

    ✅ 2-Year Warranty   |   ✈️ Worldwide Shipping

    Payment Methods:

    Description

     

    Camjoy Dual 4K Fluorescence Endoscopy Camera System: Clarity Meets Function in ICG Imaging

    The **Camjoy Dual 4K Fluorescence Endoscopic Imaging System (Model CP702)** represents the apex of modern surgical visualization, merging the high-detail clarity of Ultra HD 4K with the functional guidance of **ICG (Indocyanine Green) Fluorescence** technology. This powerful combination allows surgeons to visualize not just anatomical structures, but also physiological function in real-time, providing immediate data on blood flow (perfusion) and lymphatic drainage.

    The CP702 system is an indispensable tool in surgical oncology and plastic/reconstructive surgery. It enables the precise identification of sentinel lymph nodes, accurate assessment of tumor margins, and critical evaluation of tissue viability during flap procedures. Our system ensures a fluid, instantaneous transition between standard white light and ICG fluorescence mode, providing a seamless workflow that rivals top-tier dedicated fluorescence platforms like the **Olympus VISERA ELITE II** and **Stryker SPY** systems.

    Dual Modality: White Light and Functional Fluorescence

    1. True Dual 4K Sensor Technology

    The system utilizes a specialized sensor array and processor optimized for capturing both visible light (white light 4K) and near-infrared (ICG fluorescence) information simultaneously. This ensures that the functional information (fluorescence) is perfectly overlaid onto the high-resolution anatomical view, preventing spatial ambiguity.

    2. Real-Time Tissue Perfusion Assessment

    By administering ICG dye, surgeons can switch to the fluorescence mode to visualize blood flow. This is critical in gastrointestinal surgery for checking anastomosis integrity, reducing the risk of post-operative leaks. In reconstructive surgery, it confirms the viability of transplanted tissue or flaps, significantly lowering the risk of graft failure.

    3. Precision Lymph Node and Tumor Mapping

    The CP702 provides a non-radioactive method for **sentinel lymph node mapping**, making it safer and faster than traditional techniques. The clarity of the 4K image, combined with the illuminated lymphatics, allows for highly accurate excision of cancerous tissues and affected nodes, a major advantage in gynecology and colorectal oncology.

    4. Instant Mode Switching

    The CP702 CCU is engineered for **zero-lag mode switching**. A simple button press instantly transitions the entire video chain between 4K white light and 4K fluorescence, allowing the surgical team to maintain focus without interrupting the procedure.

    Advanced Clinical Use Cases

    The CP702 system is essential for:

    • Surgical Oncology: Accurate localization of primary and secondary tumors in breast, liver, lung, and colorectal cancers.
    • Vascular Surgery: Real-time assessment of vessel occlusion or flow, ensuring successful vascular interventions.
    • Plastic & Reconstructive Surgery: Vital assessment of tissue flap perfusion prior to closure, maximizing procedural success.
    • General Surgery: Confirming the integrity of bowel resections (anastomoses) to mitigate complications.

    Competitive Positioning in the Global Fluorescence Market

    Fluorescence imaging is a premium technology, often carrying a high barrier to entry. The Camjoy CP702 breaks this barrier by offering a Dual 4K ICG platform at a globally accessible price, while maintaining the performance standards of systems like **Richard Wolf’s Fluorescence ENDOCAM** or the **Stryker SPY Elite**. This strategy makes advanced oncology technology available to specialized hospitals in emerging **GEO regions** (including Latin America and parts of Asia) that previously could not afford entry.

    Our commitment to universal optics and easy integration with existing OR equipment (such as **Karl Storz** telescopes) minimizes the total cost of ownership, making the CP702 the smartest financial decision for hospitals expanding their minimally invasive cancer program.

    Technical Specifications Summary

    Parameter Specification Notes
    Imaging Modalities 4K White Light + 4K ICG Fluorescence Dual-mode operation.
    Resolution 3840 x 2160 (Ultra HD 4K) High resolution in both modes.
    Fluorescence Dye Indocyanine Green (ICG) Standard medical tracer compatibility.
    CCU Model  CP702 Dedicated Processor Optimized for spectral fusion.
    Safety Features Integrated ICG Excitation Filter System Protects vision and ensures clarity.
    Camjoy Electronic Technology Co., Ltd.
    Website: www.camjoymed.com | Whatsapp: +8617751967771 | Email: [email protected]